Shop online atUser’s Guideomega.comomega.comTM®www.omega.com e-mail: http://omegamanual.infoFor latest information andproduct manual visitwww.omegama
10PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA=(IN.) TYPE Gallons Liters* in GPM in LPMPOLYPROPYLENE FITTINGS (DIN/ISO ,BS, ANSI)½ FP-
11PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA=(IN.) TYPE Gallons Liters* in GPM in LPMCARBON STEEL TEES ON SCH 40 PIPE½ FM-5305CS 1572
12PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA=(IN.) TYPE Gallons Liters* in GPM in LPMBRONZE TEES ON SCH 40 PIPE1 FP-5310BR 582.34 153
1310.2. Troubleshooting10. MaintenanceThe FMG-3000 series Magmeter requires very little maintenance. There are no user-serviceable components in the M
1411. Ordering InformationOrder number Output Body material/Electrode material, Pipe size rangeFMG-3001-PP Freq PP/316SS, 0.5 to 4 in.FMG-3101-PP
WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date o
6-2551.090-OM (F-3/12) M-4210/0312Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop online at www.o
Servicing North America:USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certifi ed Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-m
31 2 3 4 JP2 FREQUENCY OUT DO NOT REMOVE Connect output signals and power to this 4-terminal block. 2. 4. 3. 3. Sensor Type Pipe Size Jumper Posit
4SAFETY INSTRUCTIONS1. Depressurize and vent system prior to installation or removal.2. Confi rm chemical compatibility before use.3. Do not exceed m
53. Installation: Pipe fi ttingsOmega offers a wide selection of installation fi ttings that control the position of the Magmeter electrodes in relati
6Important:• The directional arrow on the body of the sensor must be pointed DOWNSTREAMfor correct operation.• The FLOW arrow decal can be placed di
76. General Installation and Grounding TipsSensor conditioningThe Magmeter output signal may be unstable immediately after installation. Allowing th
8• The FMG-3001 and FMG-3101 Magmeters output an open collector frequency signal.• A 10 KΩ pull up resistor must be connected between terminals 1 an
99. Calibration Data: K-Factors* and Full Scale Current ValuesPlastic Installation Fittings: PVC Tees and SaddlesPIPE SIZE FITTING K-Factor K-Fact